OMA-300 UV ZETA Analyzer
Continuously measure the concentration of substances in liquid or gaseous components.
Using a brand-new Zeta™ spectrophotometer, precise measurements can be made in the deep ultraviolet region from 190 to 435 nm with a resolution of 0.5 nm.
Product Features
Instrument Features
- Continuously measure the concentration of chemical substances in gaseous or liquid samples.
- All-solid-state design, no moving parts, low maintenance requirements.
- The flow cell is connected to the instrument via armored optical fiber, ensuring that the sample never enters the instrument’s interior, thus providing high safety.
Analysis application
The OMA-300 UV ZETA analyzer provides real-time concentration data by measuring the absorbance of liquids or gases and correlating the optical signal with the chemical concentration of the substance using Beer-Lambert’s law. The instrument employs a UV detector and simultaneously scans the wavelength range from 190 to 435 nanometers. Technical principle:
OMA’s ZETA spectrometer determines the concentration of chemical substances by monitoring changes in the ultraviolet absorption spectrum of a sample. The system measures absorbance in the 190–435 nm range and quantifies the intensity of light absorbed by the sample. The OMA instrument then converts this raw data into high-precision absorbance spectra.
For a spectrophotometer, the higher the transmittance, the more reliable the initial data you can obtain. These principles guided the design and development of the Zeta™ UV spectrophotometer—namely, maximizing light transmission while minimizing conventional optical noise as much as possible.
Zeta™ Spectrophotometer

Internal structure

Sample system
Materials in contact with the sample include: SS316 and SS316L, fluororubber, and quartz glass.
Technical concept
Product Specifications
Note: Therefore, all the following parameters are based on the assumption that sample pretreatment and installation & commissioning have been reviewed and approved by AAI. For any other configuration arrangements, please consult AAI sales.
| Measurement principle | Ultraviolet Spectrophotometry |
|---|---|
| Detector | Zeta™ UV Spectrophotometer |
| Measurement band | 190–435 nm |
| Light source | Pulsed xenon lamp light source, with a service life of five years. |
| Optical signal transmission | 600-micron core, 1.8-meter-long optical cable; other lengths available upon request. |
| Sample Preprocessing | Customized design for different applications |
| Analyzer calibration | Before leaving the factory, the system is calibrated using a standard gas that has been certified by the manufacturer; the system’s accuracy is ensured by an automatic zeroing function. |
| Reading verification | Quickly and easily verify using standard samples and self-diagnosis functions. |
| Controller | Industrial controller equipped with an LCD touch screen and ECLIPSE™ operating software. |
| Data storage | Pure solid-state drive |
Runtime environment
| Analyzer environmental conditions | Suitable for both indoor and outdoor use; no analysis cabin required. |
|---|---|
| Ambient temperature | Standard: 0 to 35 degrees Celsius Optional: -20 to 60 degrees Celsius To avoid thermal radiation, it is recommended to install the analyzer under a sunshade when exposed to direct sunlight. |
| Sample temperature | Standard –20 to 70 degrees Celsius Optional: When equipped with a cooling extension device, the maximum temperature can reach up to 150 degrees Celsius. |
| Sample pressure | Standard flow cell: 206 bar (3000 psi) |
Power requirements
| Voltage | 85–264 VAC single-phase |
|---|---|
| Power consumption | 45 watts |
Output
| Standard output | One measured substance corresponds to a 4-20 milliamp analog output channel (with optional upgrades to support additional channels); two digital outputs correspond to alarm and pre-processing control. |
|---|---|
| Optional output | Modbus TCP/IP; RS-232; RS-485; Fieldbus; Profibus; HART |