OMA Hydrogen Sulfide Online Analysis

OMA Hydrogen Sulfide Online Analysis


AAI’s best-selling analyzer

Using the advanced NOVA II UV-Vis diode-array spectrophotometer, we can achieve full-spectrum monitoring, avoid component interference, eliminate measurement errors, and enhance accuracy.

The measurement range spans from as low as 0–10 ppm to as high as 0–100%, and the range can be adjusted at any time. It simultaneously measures up to four additional components.

High-intensity sample measurement flow cell that allows direct measurement of hot and humid samples. The sample does not come into contact with the analyzer, ensuring high safety.

The extractive sampling method offers a faster response time. With a solid-state design and no consumables, it features low maintenance costs.

Product Features


Performance

Fast, continuous readings T90 response time is less than 10 seconds. No false alarms Measure hydrogen sulfide concentration only in the absence of interference from other substances. Extremely wide dynamic measurement range It can maintain high accuracy even when the sample concentration varies significantly.

Safety and Reliability

Fully automated operation under unmanned supervision Automatic purging and zeroing function; optional remote automated control A Safer Hydrogen Sulfide Analyzer The sample never comes into contact with or enters the interior of the analyzer housing. Customize various alarm and communication outputs. 4-20mA analog output, MODBUS; HART, etc.

Flexibility

Can measure hydrogen sulfide concentrations across any range. From 0-10 ppm to 0-100% Samples that can directly measure heat/humidity The standard configuration can withstand 150° and 3,000 psi; higher configurations are available upon request. Can directly measure liquids or gases. Use the sample pretreatment system An additional 4 other components can be measured. Measure the concentrations of other components.

Maintenance cost

No consumable materials or reagents. In addition to purging with standard gas, Low maintenance requirements Simply require wiping the lenses once a month. Long-life xenon light source Average service life of 5 years Instrument with an all-solid-state structure Stands out among competitors due to the absence of moving parts.

Compatibility

Explosion-proof certificate Class I Div 1 & 2; ATEX; GOST... View certifications No-analysis cabin Can be installed directly outdoors.

Technical concept


diode-array-400w.png

Monitoring Principle

The OMA online analyzer uses the principles of ultraviolet and visible spectroscopy to determine the concentrations of chemical components in a sample. The OMA system analyzes the absorbance of the sample across wavelengths from 200 to 800 nanometers, and the data is captured by a 1024-element photodiode array detector and transmitted to a processor for data analysis, yielding high-resolution absorption spectra.

tlg-optical-assembly-v2-400w.jpg

Optical structure

The OMA process online analyzer uses a long-life xenon lamp as its light source to transmit signals that come into contact with the sample via a flow cell. This signal is emitted by the light source and transmitted through an optical fiber cable into the flow cell, where it interacts with the sample gas. Samples composed of various chemical substances exhibit unique absorption characteristics for light. The resulting light signal then exits the flow cell, travels back to the detector via another optical fiber cable.

H2S-spectra.webp

Hydrogen Sulfide Absorption Spectroscopy Diagram

To detect the concentration of hydrogen sulfide, the OMA identifies the unique absorption spectrum of pure hydrogen sulfide and uses mathematical methods to separate and isolate the hydrogen sulfide absorption spectrum from that of the sample being measured. Based on Beer-Lambert’s law, the OMA correlates the unique hydrogen sulfide absorption spectrum with the actual hydrogen sulfide concentration.

oma-h2s-software-400w.webp

User interface

AAI’s proprietary ECLIPSE software processes the acquired spectral data into actual concentration readings. On the touchscreen controller, the analyzer operator can easily switch between different interfaces—such as trend graphs, spectra plots, concentration readings, and more—and can independently and at any time set and adjust alarms, outputs, purge functions, zeroing, and other parameters.

analyzer-safety-banner-400w.webp

Multi-component measurement

Most analyzers directly introduce the sample into the analyzer’s housing for measurement. However, if the sample is toxic, highly corrosive, or explosive, this could be extremely dangerous. The OMA design is unique: instead of introducing the sample into our analyzer, we guide the optical signal into the sample itself. The sample flows only through a flow cell and never comes into contact with the analyzer. The flow cell is connected to the analyzer via an optical fiber cable.